SE Series Test (in house)

Drop test
Units were loaded with weights (see list below) and dropped at different angles from a 6’-10” platform onto a concrete surface. Cases maintained their watertight integrity and remained closed. A small percentage (<10%) sustained broken tall rib. Tests were successful.



UNIT



WEIGHT

SE120

2.0 lbs

SE300

4.9 lbs

SE520

15.7 lbs

SE710

20.0 lbs

SE720

35.0 lbs

SE920

35.0 lbs

SE1220

35.0 lbs


Impact test (SE920 and SE1220 not yet tested)
This test was performed by dropping a 4.5 lb cylindrical piece of steel onto the center of the top and then onto the bottom of each case from a height of 6’. The test was performed three times on each surface. No material failure or cracks were found.
Handle test (SE920 and SE1220 not yet tested)
Repetitive impact test. 15 lbs of weight was added to each case. Cases were then hung by their handle and given “jolt” tests. Every 6 seconds, for 48 hours the cycle machine lifted and dropped each case. Neither the handle, the handle pin nor the case itself showed any signs of stress.
Weight test (SE920 and SE1220 not yet tested)
Cases were loaded with 75 lbs of steel, and hung by their handle for 60 hours. No stress marks were found in handle, pin, latches, hinges or any component of the case.